Skip to content
  • Sales: 800-706-0906  |  24/7 Service: 877-340-0141

  • POWER CALCULATOR
  • CONTACT
  • SEARCH
Global Power SupplyGlobal Power Supply
  • Inventory
    • Automatic Transfer Switches
    • Used Diesel Generators
    • Mobile Diesel Generators
    • Diesel Generators
    • Natural Gas Generators
    • UPS Systems
    • Lithium UPS Systems
    • Mobile BESS
    • Energy Storage
    • Battery Cabinets
    • Maintenance Bypass
    • Fuel Tanks
    • Load Banks
    • Batteries
  • Solutions
    • By Industry
      • Agriculture
      • Broadcast Event
      • Construction
      • Data Center
      • Distribution
      • Education
      • Facility Management
      • Food and Beverage
      • Government
      • Hospitals and Healthcare
      • Manufacturing
      • Oil and Gas Industry
      • Public Safety Power Shutoffs
      • Renewables
      • Transportation
      • Utilities
      • Water Treatment
    • By Equipment
      • Automatic Transfer Switches
      • Battery and Energy Storage
      • Diesel Generators
      • Fuel Cell
      • Fuel Tanks
      • Load Banks
      • Microgrid
      • Natural Gas Generators
      • Power Distribution
      • Turnkey Solutions
      • UPS Trailers
      • UPS Backup Systems
      • We Buy Sell and Trade
  • Power Rentals
    • UPS Rental Trailers
    • UPS Rental Systems
    • Mobile Diesel Generators
    • Natural Gas Generators
  • Services
    • Engineering
      • Arc Flash Study
      • Battery Energy Storage Study
      • Generator Application Study
      • Microgrid Study
      • Short Circuit Study
      • UPS Backup System Study
    • Equipment
      • Power Rentals
      • Decomissioning Services
      • Emergency Response
      • Emission Compliance Studies
      • Engineered Design
      • Fuel Services and Management
      • Installation Services
      • Preventative Maintenance
      • Project Management
      • Remote Monitoring
      • Site Surveys
  • Resources
    • Power Calculator
    • Blog
    • Power Outage Map
    • Case Studies
    • Critical Power Glossary
  • About Us
    • Company Profile
    • Leadership
    • Locations
    • Careers
    • News & Events
  • Login
  • Quotes
  •     
Home / Industrial UPS System
Eaton 9355 30 kVA
SKU: 9888

Eaton 9355 30 kVA (#9888)

Add to quote
This product is already in your quote request list.
Browse the list
SKU: 9888 Category: Industrial UPS System Brand: EatonCondition:NewkW:27kVA:30
FEATURED
  • Cummins 60 kW C60N6 Cummins 60 kW C60N6

 

 

  • Specifications
  • Description
  • Video
  • Downloads

Product Details

UPS Details

SKU 9888
Manufacturer Eaton
Condition New
Year 2024
Model 9355 – 30 kVA
Model Family 9355
kW 27
kVA 30
Phase 3
Input Voltage 208
Output Voltage 208
Input Wiring 4 wire
Output Wiring 4 wire
Lead Time (Weeks) 4 to 6
ID# 27811

Battery Details

Battery System Internal
Internal Batteries Yes
Batteries Included Y
Battery Type Lead Acid
Battery Duration (Minutes) 11

Notes

Agility, scalability and space efficiency – with greater standard runtime

The Eaton 9355 is a mid-size, three-phase uninterruptible power system (UPS) that delivers superior power protection for the ever-expanding loads in today’s space-constrained data centers.

The double-conversion topology of the 9355 means that it protects IT infrastructure from all of the most common power problems to give data center managers greater peace of mind. The 9355 also offers an industry-leading combination of flexibility, scalability and power density—all in an innovative, high-efficiency package.

The 9355’s sleek, end-of-row tower design is available in 10 kVA and 20 kVA configurations, upgradeable to 15 kVA and 30 kVA, respectively, and offers the smallest footprint of any comparable UPS. Standard internal batteries often eliminate the need for costly and space-consuming external battery cabinets.

An on-board power distribution module gives data center managers additional flexibility by helping to preserve valuable rack space and making the rack-based environment truly plug and play. This module can be configured for hardwired output or with a variety of output receptacles, reducing site preparation and installation expenses.

Up to four 9355 UPSs can be paralleled for either redundancy or extra capacity using Eaton’s patented Powerware® Hot Sync® paralleling technology. Powerware Hot Sync also enables wireless paralleling in the event of a communications failure, providing the industry’s only truly redundant paralleling solution.

The 9355’s space-efficient design and outstanding performance and reliability make it perfect for corporate, telecom, healthcare, banking, industrial and retail applications. Combined with Eaton’s world-class warranty and service plans, expert technical support, and broad selection of options—and backed by 40 years of R&D excellence—the 9355 is the ideal power protection solution for small data centers.


Product Snapshot

  • Power rating: 10, 15, 20 and 30 kVA at 0.9 power factor (three phase)
  • Form factor: Small-footprint tower, black
  • Topology: Double conversion
  • Battery backup: Up to 22 minutes typical, extendable up to three hours
  • Input voltage: 208V/120V or 220V/127V
  • Output voltage: 208V/120V or 220V/127V 480V: 120V/208V or 600V: 120/208 with input isolation transformer (at 60 Hz only)
  • Frequency: 50/60 Hz auto-sensing
  • Dimensions: 10 and 15 kVA two-high configuration: 32.2" H x 12" W x 32.5" D 10 and 15 kVA three-high configuration: 47.8" H x 12" W x 32.5" D 20 and 30 kVA: 66" H x 20" W x 34" D

Premium power protection

With the 9355 UPS, data center managers can safely eliminate the effects of electrical line disturbances and guard the integrity of their systems and equipment. The 9355 is a true double-conversion, three-phase system that can be used to prevent loss of valuable electronic information and minimize equipment downtime.
  • The 9355 continually monitors incoming electrical power and removes the surges, spikes, sags, and other irregularities that are inherent in commercial utility power
  • Working with a building’s electrical system, the 9355 supplies the clean, consistent power required by sensitive electronic equipment for reliable operation
  • During brownouts, blackouts, and other power interruptions, internal batteries provide emergency power to safeguard operation

Self-diagnosis

The 9355 constantly monitors its own operation —such as voltage, temperature and function of internal components—and sends an alarm or takes action if it detects a potential problem.


Self-correction

If it senses a problem, the 9355 instantly transfers the power path to a bypass source with zero interruption in power. When the alarm condition passes, the 9355 automatically reverts from bypass to normal power.

The 9355 UPS features a four-button graphical LCD that provides useful information such as load status, events, measurements and settings.


Advanced battery management

The 9355 UPS offers innovative technologies to maximize the health and service life of its internal and external batteries:
  • ABM technology uses a unique three-stage charging technique that significantly extends battery service life and optimizes recharge time when compared to traditional trickle charging
  • emperature-compensated charging monitors battery temperature and adjusts the charge rate accordingly, which properly charges the battery and greatly extends battery life
  • An integrated battery management system tests and monitors battery health and remaining lifetime, providing user notification to guide preventive maintenance
Eaton's UPS batteries are field replaceable. One person, working alone, can easily replace a battery without disrupting data center operations or power to protected equipment.
Acrobat PDF Download Eaton 9355 Brochure

You may also like…

Riello UPS Sentryum 20 kVA

#9038

Industrial UPS System

Riello UPS Sentryum 20 kVA

New

208V / 208V

3-phase

kVA: 20

Runtime (min.) 4

Est. Lead Time (weeks): 4 to 6

Eaton 93PM 40 kVA

#9894

Industrial UPS System

Eaton 93PM 40 kVA

New

208V / 208V

3-phase

kVA: 40

Est. Lead Time (weeks): 4 to 6

Xtreme Power Conversion M90U140 140 kVA

#9956

Industrial UPS System

Xtreme Power Conversion M90U140 140 kVA

New

120/208V / 120/208V

3-phase

kVA: 140

Runtime (min.) 5

Est. Lead Time (weeks): 4 to 5

Xtreme Power Conversion M90U 30 kVA

#9943

Industrial UPS System

Xtreme Power Conversion M90U 30 kVA

New

120/208V / 120/208V

3-phase

kVA: 30

Runtime (min.) 6

Est. Lead Time (weeks): 4 to 5

Trusted Generator Brands & Partners

SALES

  • Over $50M in Inventory
  • Used Diesel Generators
  • Mobile Diesel Generators
  • Natural Gas Generators
  • Automatic Transfer Switches
  • Industrial UPS Systems
  • Energy Storage Systems
  • We Buy Generators
  • We Buy UPS Systems

MANUFACTURERS

  • See All Brands
  • Cummins
  • MTU Onsite Energy
  • Caterpillar
  • Hipower Generators
  • Mesa Solutions
  • Toshiba UPS
  • ABB Switches
  • ASCO ATS

Support

  • Power Calculator
  • Order Tracking
  • Shipping Information
  • Terms of Sale
  • Returns & Damages
  • Warranty Policy
  • Support

COMPANY

  • Blog
  • About Us
  • Leadership
  • Careers
  • Contact Us
  • Subscribe

Our Locations

GPS Our Locations Map
Global Power SupplyGlobal Power Supply
1-800-706-0906

Corporate Headquarters: Santa Barbara, California - Warehouse: Carson City, Nevada - Warehousing: Nevada, Texas, Florida, Minnesota, Kansas
All logos and trademarks used on this website belong to their respective owners.

Terms of Use and Privacy Policy

© 2026 Global Power Supply, LLC. All Rights Reserved

 

  • 800-706-0906
  • My Quote Request
  • My Account
  • Power Calculator
  • Contact Us
  • Inventory
    • Automatic Transfer Switches
    • Used Diesel Generators
    • Mobile Diesel Generators
    • Diesel Generators
    • Natural Gas Generators
    • UPS Systems
    • Lithium UPS Systems
    • Mobile BESS
    • Energy Storage
    • Battery Cabinets
    • Maintenance Bypass
    • Fuel Tanks
    • Load Banks
    • Batteries
  • Solutions
    • Agriculture
    • Broadcast Event
    • Construction
    • Data Centers
    • Distribution
    • Education
    • Facility Management
    • Food and Beverage
    • Government
    • Hospitals and Healthcare
    • Manufacturing
    • Oil and Gas Industry
    • Power Safety Power Shutoffs
    • Renewables
    • Transportation
    • Utilities
    • Water Treatment
    • Automatic Transfer Switches
    • BESS Battery Storage
    • Diesel Generators
    • Fuel Cell
    • Fuel Tanks
    • Load Banks
    • Microgrids
    • Natural Gas Generators
    • Power Distribution
    • Turnkey Solutions
    • UPS Rentals
    • UPS Backup Systems
    • We Buy Sell and Trade
  • Power Rentals
    • UPS Rental Trailers
    • UPS Rental Systems
    • Mobile Diesel Generators
    • Natural Gas Generators
  • Services
    • Engineering
      • Arc Flash Study
      • Battery Energy Storage Study
      • Generator Application Study
      • Microgrid Study
      • Short Circuit Study
      • UPS Backup System Study
    • Equipment
      • Power Rentals
      • Decomissioning Services
      • Emergency Response
      • Emission Compliance Studies
      • Engineered Design
      • Fuel Services and Management
      • Installation Services
      • Preventative Maintenance
      • Project Management
      • Remote Monitoring
      • Site Surveys
  • Resources
    • Blog
    • Power Outage Map
    • Case Studies
    • Critical Power Glossary
  • About Us
    • Company Profile
    • Leadership
    • Locations
    • Careers
    • News & Events
  • POWER CALCULATOR
  • CONTACT
  • SEARCH
  • Login
  •     
We use cookies on our website to improve functionality and performance. If you agree and consent to the use of cookies, please click Accept.AcceptPrivacy policy